Novel simple templates for reproducible positioning of skin applicators in brachytherapy.

2016

Purpose : Esteya and Valencia surface applicators are designed to treat skin tumors using brachytherapy. In clinical practice, in order to avoid errors that may affect the treatment outcome, there are two issues that need to be carefully addressed. First, the selected applicator for the treatment should provide adequate margin for the target, and second, the applicator has to be precisely positioned before each treatment fraction. In this work, we describe the development and use of a new acrylic templates named Template La Fe-ITIC. They have been designed specifically to help the clinical user in the selection of the correct applicator, and to assist the medical staff in reproducing the po…

0106 biological sciencesEngineering drawingmedicine.medical_specialtyMedical staffelectronic brachytherapymedicine.medical_treatmentTreatment outcomeBrachytherapybrachytherapylcsh:Medicine01 natural sciences03 medical and health sciences0302 clinical medicineMargin (machine learning)medicineRadiology Nuclear Medicine and imagingMedical physicsReview Paperskin cancerbusiness.industrylcsh:RtemplateThin sheetClinical Practiceskin applicatorsTemplateOncology030220 oncology & carcinogenesisbusiness010606 plant biology & botanyJournal of contemporary brachytherapy
researchProduct

Depth determination of skin cancers treated with superficial brachytherapy: ultrasound vs. histopathology

2014

Purpose: The purpose of this study is to compare high frequency ultrasonography (HFUS) and histpathologic assessment done by punch biopsy in order to determine depth of basal cell carcinoma (BCC), in both superficial and nodular BCCs prior to brachytherapy treatment. Material and methods: This study includes 20 patients with 10 superficial and 10 nodular BCCs. First, punch biopsy was done to confirm the diagnosis and to measure tumour depth (Breslow rate). Subsequently, HFUS was done to measure tumour depth to search for correlation of these two techniques. Results: Neither clear tendency nor significance of the punch biopsy vs. HFUS depth determination is observed. Depth value differences …

Original Papermedicine.medical_specialtyPunch Biopsyskin cancerelectronic brachytherapyultrasoundbusiness.industrymedicine.medical_treatmentBrachytherapyUltrasoundpunch biopsyPlanning target volumemedicine.diseaseSurgerybasal cell carcinomaOncologymedicineSmall LesionHigh frequency ultrasonographyskin brachytherapyRadiology Nuclear Medicine and imagingHistopathologyBasal cell carcinomaNuclear medicinebusinessJournal of Contemporary Brachytherapy
researchProduct

Failure mode and effects analysis of skin electronic brachytherapy using Esteya® unit

2016

Purpose: Esteya® (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden) is an electronic brachytherapy device used for skin cancer lesion treatment. In order to establish an adequate level of quality of treatment, a risk analysis of the Esteya treatment process has been done, following the methodology proposed by the TG-100 guidelines of the American Association of Physicists in Medicine (AAPM). Material and methods: A multidisciplinary team familiar with the treatment process was formed. This team developed a process map (PM) outlining the stages, through which a patient passed when subjected to the Esteya treatment. They identified potential failure modes (FM) and each individual FM…

medicine.medical_specialtyQuality managementFrequency of occurrenceelectronic brachytherapymedia_common.quotation_subjectmedicine.medical_treatmentBrachytherapylcsh:MedicineTG-10003 medical and health sciences0302 clinical medicineRisk analysis (business)MedicineRadiology Nuclear Medicine and imagingQuality (business)Medical physicsQAFMEAmedia_commonOriginal Paperskin cancerBrachytherapy devicebusiness.industry030503 health policy & serviceslcsh:RTreatment processEsteyaOncology030220 oncology & carcinogenesis0305 other medical sciencebusinessFailure mode and effects analysisJournal of Contemporary Brachytherapy
researchProduct

Dosimetric characteristics of a new unit for electronic skin brachytherapy

2013

PURPOSE: Brachytherapy with radioactive high dose rate (HDR) (192)Ir source is applied to small skin cancer lesions, using surface applicators, i.e. Leipzig or Valencia type. New developments in the field of radiotherapy for skin cancer include electronic brachytherapy. This technique involves the placement of an HDR X-ray source close to the skin, therefore combining the benefits of brachytherapy with the reduced shielding requirements and targeted energy of low energy X-rays. Recently, the Esteya(®) Electronic Brachytherapy System (Esteya EBS, Elekta AB-Nucletron, Stockholm, Sweden) has been developed specifically for HDR brachytherapy treatment of surface lesions. The system provides rad…

Original Paperelectronic brachytherapybusiness.industrymedicine.medical_treatmentTreatment durationSuperficial radiotherapyBrachytherapyElectronic skinsuperficial radiotherapyRadiation therapyLow energyOncologynonmelanoma skin-cancermedicineskin brachytherapyRadiology Nuclear Medicine and imagingNuclear medicinebusinessDose rateDepth doseJournal of Contemporary Brachytherapy
researchProduct

Commissioning and periodic tests of the Esteya® electronic brachytherapy system

2015

A new electronic brachytherapy unit from Elekta, called Esteya(®), has recently been introduced to the market. As a part of the standards in radiation oncology, an acceptance testing and commissioning must be performed prior to treatment of the first patient. In addition, a quality assurance program should be implemented. A complete commissioning and periodic testing of the Esteya(®) device using the American Association of Physicists in Medicine (AAPM), Groupe Europeen de Curietherapie and the European Society for Radiotherapy & Oncology (GEC-ESTRO) guidelines for linacs and brachytherapy units as well as our personal experience is described in this paper. In addition to the methodology, r…

Review Papermedicine.medical_specialtyTraceabilityPeriodic testingelectronic brachytherapybusiness.industryProject commissioningmedicine.medical_treatmentBrachytherapyquality assuranceTest (assessment)EsteyaOncologyAcceptance testingRadiation oncologyMedicinecommissioningRadiology Nuclear Medicine and imagingMedical physicsbusinessQuality assuranceJournal of Contemporary Brachytherapy